Infrared
Infrared
Product | Description | Accuracy | Power Supply | Dimension | Measurement range | Humidity range | Target Gas | Operating temperature | Output |
---|---|---|---|---|---|---|---|---|---|
|
C4H10-LF-3V NDIR module for the measure of Butane. |
Accuracy
± 3% F.S.
|
Power Supply
3.3 Vdc
|
Dimension
40 x 38 x 18.5 mm
|
Measurement range
0-5000 ppm
0-18000 ppm
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Butane
|
Operating temperature
-20°C / +50°C
|
Output
I2C
UART
Analog (0.5V - 3.0V)
|
|
C4H10-S3 NDIR module for the measure of Butane. |
Accuracy
± 2% F.S.
|
Power Supply
5.0 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Measurement range
0-100% LEL
0-18000 ppm
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Butane
|
Operating temperature
-20°C / +50°C
|
Output
I2C
PWM
UART
Analog (0.5V - 4.5V)
|
|
C4H10-S3-3V NDIR module for the measure of Butane. |
Accuracy
± 2% F.S.
|
Power Supply
3.3 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Measurement range
0-100% LEL
0-18000 ppm
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Butano
|
Operating temperature
-20°C / +50°C
|
Output
I2C
PWM
UART
Analog (0.5V - 3.0V)
|
|
CD-100 Transmitter board with NDIR sensor for Carbon Dioxide (CO2) |
Accuracy
± 30ppm ± 5% of reading
|
Power Supply
24 VDC
24 VAC
|
Dimension
123 x 70 x 43 mm
|
Measurement range
0-2000 ppm
0-3000 ppm
0-5000 ppm
0-10000 ppm
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Carbon dioxide
|
Operating temperature
-10°C / +60°C
-40°C / 40°C
|
Output
RS485
0-20 mA
4-20 mA
0-10 Vdc
2-12 Vdc
|
|
CD-200 Transmitter board with NDIR sensor for Carbon Dioxide (CO2) |
Accuracy
± 30ppm ± 5% of reading
|
Power Supply
24 VDC
24 VAC
|
Dimension
123 x 70 x 43 mm
|
Measurement range
0-2000 ppm
0-5000 ppm
0-10000 ppm
|
Humidity range
0-99% RH
0-95% RH
|
Target Gas
Carbon dioxide
|
Operating temperature
-10°C / +60°C
|
Output
RS485
0-20 mA
2-10 Vdc
4-20 mA
0-10 Vdc
Relay
|
|
CD-300 Transmitter board with NDIR sensor for Carbon Dioxide (CO2) |
Accuracy
± 30ppm ± 5% of reading
|
Power Supply
24 VDC
|
Dimension
123 x 70 x 43 mm
|
Measurement range
0-2000 ppm
0-3000 ppm
0-5000 ppm
0-10000 ppm
0-2%
0-3%
0-5%
0-7%
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Carbon dioxide
|
Operating temperature
-10°C / +60°C
|
Output
4-20 mA
2-10 Vdc
0-10 Vdc
0-20 mA
|
|
CD-300-D3 Transmitter board with NDIR sensor for Carbon Dioxide (CO2) |
Accuracy
± 30ppm ± 5% of reading
|
Power Supply
24 VDC
|
Dimension
123 x 70 x 43 mm
|
Measurement range
0-2000 ppm
0-3000 ppm
0-5000 ppm
0-10000 ppm
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Carbon dioxide
|
Operating temperature
-10°C / +60°C
|
Output
4-20 mA
0-10 Vdc
2-10 Vdc
0-20 mA
|
|
CD-400 Transmitter board with NDIR sensor for Carbon Dioxide (CO2) |
Accuracy
± 50ppm ± 5% of reading
|
Power Supply
24 VAC
24 VDC
|
Dimension
123 x 70 x 43 mm
|
Measurement range
0-2000 ppm
0-3000 ppm
0-5000 ppm
0-10000 ppm
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Carbon dioxide
|
Operating temperature
-10°C / +60°C
|
Output
4-20 mA
2-10 Vdc
0-10 Vdc
0-20 mA
Relay
|
|
CH4-CD300 Transmitter board with NDIR sensor for Methane (CH4) |
Accuracy
± 3% F.S.
|
Power Supply
24 VDC
|
Dimension
123 x 70 x 43 mm
|
Measurement range
0-100% LEL
0-50000 ppm
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Methane
|
Operating temperature
-20°C / +50°C
|
Output
4-20 mA
2-10 Vdc
0-10 Vdc
0-20 mA
|
|
CH4-D3 NDIR module for the measure of CH4 |
Accuracy
± 3% F.S.
|
Power Supply
5.0 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Measurement range
0-50000 ppm
|
Humidity range
0-99% RH
0-95% RH
|
Target Gas
Methane
|
Operating temperature
-20°C / +50°C
|
Output
I2C
UART
Analog (0.5V - 4.5V)
PWM
|