HUMI.sens Humidity sensor Humidity sensor | ||||||||||||||
|
INFRA.sens® AK2 SF6 The INFRA.sens was specially developed for high-quality NDIR gas analysis. In the design phase, special emphasis was placed on high stability and a low detection limit. |
Accuracy
±2 % F.S.
|
Energetic consumption
< 10 Watt
|
Measurement range
<1 Vol.%
|
Temperature range
5°C – 45°C
|
Target Gas
Multigas
|
Response Time
3 seconds (T90)
|
Output
RS232, Can, Analogic
|
|||||||
|
INFRA.sens® AK20 The INFRA.sens was specially developed for high-quality NDIR gas analysis. In the design phase, special emphasis was placed on high stability and a low detection limit. |
Accuracy
±2 % F.S.
|
Energetic consumption
< 10 Watt
|
Measurement range
<1 Vol.%
|
Temperature range
5°C – 45°C
|
Target Gas
Multigas
|
Output formats
RS232, Can, Analogica
|
Temp. drift
3 secondi (T90)
|
|||||||
|
INFRA.sens® AK250TBH The INFRA.sens was specially developed for high-quality NDIR gas analysis. In the design phase, special emphasis was placed on high stability and a low detection limit. |
Accuracy
±2 % F.S.
|
Energetic consumption
< 10 Watt
|
Measurement range
<100 Vol.%
|
Temperature range
5°C – 45°C
|
Target Gas
Multigas
|
Response Time
3 secondi (T90)
|
Output
RS232, Can, Analogica
|
|||||||
|
INLINE Safety Filter Safety filter |
Compatible sensors
Gas Analyzer Equipment
|
|||||||||||||
|
Infra.Sens AK100 The INFRA.sens was specially developed for high-quality NDIR gas analysis. In the design phase, special emphasis was placed on high stability and a low detection limit. |
Accuracy
±2 % F.S.
|
Energetic consumption
< 10 Watt
|
Measurement range
< 1 Vol.%
|
Temperature range
5°C – 45°C
|
Target Gas
Multigas
|
Response Time
3 seconds (T90)
|
Output
RS232, Can, Analog
|
|||||||
|
Infra.Sens AK250 The INFRA.sens was specially developed for high-quality NDIR gas analysis. In the design phase, special emphasis was placed on high stability and a low detection limit. |
Accuracy
±2 % F.S.
|
Energetic consumption
< 10 Watt
|
Measurement range
< 2000ppm
|
Temperature range
5°C – 45°C
|
Target Gas
Multigas
|
Response Time
3 seconds (T90)
|
Output
RS232, Can, Analog
|
|||||||
|
Infra.Sens AK5 The INFRA.sens was specially developed for high-quality NDIR gas analysis. In the design phase, special emphasis was placed on high stability and a low detection limit. |
Accuracy
±2 % F.S.
|
Energetic consumption
< 10 Watt
|
Measurement range
< 100 Vol.%
|
Temperature range
5°C – 45°C
|
Target Gas
Multigas
|
Response Time
3 seconds (T90)
|
Output
RS232, Can, Analog
|
|||||||
|
Infra.Sens AK50 The INFRA.sens was specially developed for high-quality NDIR gas analysis. In the design phase, special emphasis was placed on high stability and a low detection limit. |
Accuracy
±2 % F.S.
|
Energetic consumption
< 10 Watt
|
Measurement range
< 20 Vol.%
|
Temperature range
5°C – 45°C
|
Target Gas
Multigas
|
Response Time
3 seconds (T90)
|
Output
RS232, Can, Analog
|
|||||||
|
IoT-S300E NDIR module for CO2 measurement |
Accuracy
± 50ppm ± 5% of reading
|
Measurement range
400-5000 ppm
|
Target Gas
Carbon dioxide
|
Output
I2C
UART
|
Power Supply
5.0 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Humidity range
0-95% RH
|
Operating temperature