Infrared
Infrared
Product | Description | Accuracy | Power Supply | Dimension | Measurement range | Humidity range | Operating temperature | Output | Target Gas | Working temperature |
---|---|---|---|---|---|---|---|---|---|---|
|
AQM-100 AQM-100 series transmitters which can measure gases such as CO2, VOCs, Temperature, Humidity. |
Accuracy
± 30ppm ± 5% of reading
|
Power Supply
12 Vdc
|
Dimension
118 x 74 x 22 mm
|
Measurement range
0-10000 ppm
|
Humidity range
0-95% RH
|
Operating temperature
0°C / +50°C
|
Output
RS232
RS485
|
||
|
B-530 NDIR module for the measure of CO2. With its compact size and availability in Moisture proof version too, it is particularly suitable for agricultural field. |
Accuracy
± 30ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Power Supply
12.0 Vdc
|
Dimension
65 x 50 x 20 mm
|
Measurement range
0-2000 ppm
0-3000 ppm
0-5000 ppm
0-10000 ppm
0-5%
|
Humidity range
0-95% RH
0-99% RH
|
Output
UART
Analog (0.5V - 4.5V)
|
Target Gas
Carbon dioxide
|
Working temperature
-20°C / +65°C
|
|
|
C2H4-CD300 Transmitter board with NDIR sensor for Ethylene (C2H4) |
Accuracy
± 3% F.S.
|
Power Supply
24 VDC
|
Dimension
123 x 70 x 43 mm
|
Measurement range
0-100% LEL
0-27000 ppm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-20°C / +50°C
|
Output
4-20 mA
2-10 Vdc
0-10 Vdc
0-20 mA
|
Target Gas
Ethylene
|
|
|
C2H4-D3 NDIR module for the measure of Ethylene (C2H4) |
Accuracy
± 3% F.S.
|
Power Supply
5.0 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Measurement range
0-27000 ppm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-20°C / +50°C
|
Output
I2C
UART
Analog (0.5V - 4.5V)
PWM
|
Target Gas
Ethylene
|
|
|
C2H4-D3-3V NDIR module for the measure of Ethylene (C2H4) |
Accuracy
± 3% F.S.
|
Power Supply
3.3 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Measurement range
0-27000 ppm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-20°C / +50°C
|
Output
I2C
UART
Analog (0.5V - 3.0V)
PWM
|
Target Gas
Ethylene
|
|
|
C2H4-LD-3V NDIR module for the measure of Ethylene |
Accuracy
± 3% F.S.
|
Power Supply
3.3 Vdc
|
Dimension
40 x 38 x 18.5 mm
|
Measurement range
0-2000 ppm
0-27000 ppm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-20°C / +50°C
|
Output
I2C
UART
Analog (0.5V - 3.0V)
|
Target Gas
Ethylene
|
|
|
C2H4-LF-3V NDIR module for the measure of Ethylene. |
Accuracy
± 3% F.S.
|
Power Supply
3.3 Vdc
|
Dimension
40 x 38 x 18.5 mm
|
Measurement range
0-2000 ppm
0-27000 ppm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-20°C / +50°C
|
Output
I2C
UART
Analog (0.5V - 3.0V)
|
Target Gas
Ethylene
|
|
|
C2H4-S3 NDIR module for the measure of Ethylene |
Accuracy
± 3% F.S.
|
Power Supply
5.0 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Measurement range
0-100% LEL
0-27000 ppm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-20°C / +50°C
|
Output
I2C
UART
PWM
Analog (0.5V - 4.5V)
|
Target Gas
Ethylene
|
|
|
C2H4-S3-3V NDIR module for the measure of Ethylene |
Accuracy
± 3% F.S.
|
Power Supply
3.3 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Measurement range
0-100% LEL
0-27000 ppm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-20°C / +50°C
|
Output
I2C
UART
PWM
Analog (0.5V - 3.0V)
|
Target Gas
Ethylene
|
|
|
C3H8-CD300 Transmitter board with NDIR sensor for Propane (C3H8) |
Accuracy
± 3% F.S.
|
Power Supply
24 VDC
|
Dimension
123 x 70 x 43 mm
|
Measurement range
0-100% LEL
0-21000 ppm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-20°C / +50°C
|
Output
4-20 mA
2-10 Vdc
0-10 Vdc
0-20 mA
|
Target Gas
Propane
|