Infrared
Infrared
Product | Description | Accuracy | Power Supply | Dimension | Measurement range | Humidity range | Operating temperature | Output | Target Gas | Current Consumption (mA) | Working temperature |
---|---|---|---|---|---|---|---|---|---|---|---|
|
M-530 Transmitter board based on CO2 NDIR sensor |
Accuracy
± 30ppm ± 5% of reading
|
Power Supply
9~15 VDC
|
Dimension
123 x 70 x 43 mm
|
Measurement range
0-2000 ppm
0-3000 ppm
0-5000 ppm
0-10000 ppm
0-50000 ppm
|
Humidity range
0-95% RH
|
Operating temperature
0°C / +50°C
|
Output
UART
Analog (0.5V - 4.5V)
|
|||
|
MT-200 Modulo USB NDIR per la misura di CO2 per Qualità dell'aria. |
Accuracy
± 30ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Power Supply
USB
|
Dimension
55.6 x 19.4 x 10.3 mm
|
Measurement range
0-10000 ppm
0-5%
0-10%
|
Humidity range
0-95% RH
|
Operating temperature
-20°C / +60°C
|
Output
USB
|
Target Gas
Carbon dioxide
|
||
|
NEXT-PM Module for PM10/2.5/1.0 measurement based on proprietary Laser technology. UART output or RS485. |
Power Supply
5.0 Vdc
|
Measurement range
0-1000 ㎍/㎥
|
Output
UART
RS485
|
Target Gas
PM2.5 / PM1.0
PM10
|
Current Consumption (mA)
250 mA
|
|||||
|
NEXT-PM Lite Compact size measurement module for particulate matter PM10/2.5/1.0 based on proprietary Laser technology |
Power Supply
5.0 Vdc
|
Measurement range
0-1000 ㎍/㎥
|
Output
UART
RS485
|
Target Gas
PM2.5 / PM1.0
PM10
|
Current Consumption (mA)
<50 mA
|
|||||
|
NEXT-PM OPC Fine dust measurement module for clean rooms. |
Power Supply
5.0 Vdc
|
Output
RS485
UART
|
Current Consumption (mA)
<80 mA
|
|||||||
|
PSML Infrared module for PM2.5/1.0 measurement based on proprietary IrED technology. UART LPO (Low Pulse Occupancy) |
Power Supply
5.0 Vdc
|
Measurement range
0-500 ㎍/㎥
|
Output
LPO (Low Pulse Occupancy)
|
Target Gas
PM2.5 / PM1.0
|
||||||
|
PSMU Infrared module for PM2.5/1.0 measurement based on proprietary IrED technology. UART output |
Power Supply
5.0 Vdc
|
Measurement range
0-500 ㎍/㎥
|
Output
UART
|
Target Gas
PM2.5 / PM1.0
|
||||||
|
S-110 NDIR module for the measure of CO2. With its compact size it is particularly suitable for several applications. |
Accuracy
± 30ppm ± 3% of reading
|
Power Supply
5.0 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Measurement range
0-2000 ppm
0-3000 ppm
0-5000 ppm
0-10000 ppm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-10°C / +60°C
|
Output
Analog (0.5V - 4.5V)
I2C
UART
|
Target Gas
Carbon dioxide
|
||
|
S-110H NDIR module for the measure of CO2. |
Accuracy
± 50ppm ± 3% of reading
|
Power Supply
12.0 Vdc
|
Dimension
39 x 32 x 13.1 mm
|
Measurement range
0-2000 ppm
0-3000 ppm
0-5000 ppm
0-10000 ppm
|
Humidity range
0-99% RH
0-95% RH
|
Operating temperature
-10°C / +60°C
|
Output
UART
I2C
PWM
Analog (0.5V - 4.5V)
|
Target Gas
Carbon dioxide
|
||
|
S-300 NDIR module for the measure of CO2. With its compact size it is particularly suitable for several applications. |
Accuracy
± 30ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Power Supply
5.0 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Measurement range
0-2000 ppm
0-3000 ppm
0-5000 ppm
0-10000 ppm
0-2%
0-3%
0-5%
|
Humidity range
0-95% RH
0-99% RH
|
Output
PWM
UART
I2C
Analog (0.5V - 4.5V)
|
Target Gas
Carbon dioxide
|
Working temperature