Product | Description | Accuracy | Power Supply | Dimension | Measurement range | Humidity range | Target Gas | Operating temperature | Output | Life expectancy | Response Time |
---|---|---|---|---|---|---|---|---|---|---|---|
|
H-250-12V NDIR module for the measure of high concentration of Carbon Dioxide (CO2) |
Accuracy
± 300ppm ± 3% of reading
|
Power Supply
12.0 Vdc
|
Dimension
50 x 69 x 20 mm
|
Measurement range
0-5%
0-10%
0-15%
0-20%
0-25%
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Carbon dioxide
|
Operating temperature
-10°C / +60°C
|
Output
PWM
I2C
UART
Analog (0.5V - 4.5V)
|
||
|
H-250-3V NDIR module for the measure of high concentration of Carbon Dioxide (CO2) |
Accuracy
± 300ppm ± 3% of reading
|
Power Supply
3.3 Vdc
|
Dimension
32.5 x 38 x 19.1 mm
|
Measurement range
0-5%
0-10%
0-15%
0-20%
0-25%
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Carbon dioxide
|
Operating temperature
-10°C / +60°C
|
Output
I2C
PWM
UART
Analog (0.5V - 3.0V)
|
||
|
H-250-5V NDIR module for the measure of high concentration of Carbon Dioxide (CO2) |
Accuracy
± 300ppm ± 3% of reading
|
Power Supply
5.0 Vdc
|
Dimension
32.5 x 38 x 19.1 mm
|
Measurement range
0-5%
0-10%
0-15%
0-20%
0-25%
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Carbon dioxide
|
Operating temperature
-10°C / +60°C
|
Output
I2C
PWM
UART
Analog (0.5V - 4.5V)
|
||
|
H2 3E 1% City Technology - Electrochemical Cell for Hydrogen |
Measurement range
0-10.000 ppm
|
Target Gas
Hydrogen
|
Output
10 ± 5 nA/ppm
|
Life expectancy
> 24 months
|
Response Time
< 70 seconds (T90)
|
|||||
|
H2 3E 4 % City Technology - Electrochemical Cell for Hydrogen |
Measurement range
0-40.000 ppm
|
Target Gas
Hydrogen
|
Output
1.0 ± 0.5 nA/ppm
|
Life expectancy
> 24 months
|
Response Time
< 60 seconds (T90)
|
|||||
|
H2S-4HS-LM City Technology (Sensoric) - Electrochemical sensor for Hydrogen sulfide (AsH3) |
Measurement range
0-100 ppm
|
Target Gas
Hydrogen sulfide
|
Output
700 ± 150 μA/ppm
|
Life expectancy
> 24 months
|
Response Time
< 30 seconds (T90)
|
|||||
|
HCN 2E 30 F City Technology - Electrochemical Cell for Hydrogen cyanide HCN |
Measurement range
0 – 30 ppm
|
Target Gas
Hydrogen cyanide
|
Output
30 ± 15 nA/ppm
|
Life expectancy
> 18 months
|
Response Time
< 30 seconds (T90)
|
|||||
|
HCN 3E 30 F City Technology - Electrochemical Cell Hydrogen cyanide HCN 3 Electrode sensor with organic electrolyte. |
Measurement range
0 – 30 ppm
|
Target Gas
Hydrogen cyanide
|
Output
60 ± 15 nA/ppm
|
Life expectancy
> 18 months
|
Response Time
< 50 seconds (T90)
|
|||||
|
HCl 3E 30 City Technology - Electrochemical cell for Hydrogen Chloride |
Measurement range
0-30 ppm
|
Target Gas
Hydrogen Chloride
|
Output
140 ± 60 nA/ppm
|
Life expectancy
> 24 months
|
Response Time
< 70 seconds (T90)
|
|||||
|
HF 3E 10 SE City Technology (Sensoric) - 3 Electrode sensor for Hydrofluoric Acid (HF) |
Measurement range
0-10 ppm
|
Target Gas
Hydrofluoric acid
|
Output
300 ± 100 nA/ppm
|
Life expectancy
> 18 months
|
Response Time
< 90 seconds (T90)
|