Nominal Range: 0-100 ppm
Maximum Overload: 500 ppm
Expected Operating Life: Two years in air
Output Signal: 0.70 ± 0.15 μA/ppm
Resolution: 0.1 ppm
Temperature Range: -40°C to +50°C
Pressure Range: Atmospheric ± 10%
Pressure Coefficient: No data
T90 Response Time: ≤30 seconds
Relative Humidity Range: 15 to 90% non-condensing
Typical Baseline Range (pure air): -0.1 to +0.4 ppm equivalent
Maximum Zero Shift (+20°C to +40°C): <0.2 ppm equivalent
Long Term Output Drift: <2% signal loss/month
Recommended Load Resistor: 10 Ω
Bias Voltage: Not required
Repeatability: <2% of signal
Output Linearity: Linear
Weight: 5 g (approx.)
Position Sensitivity: None
Storage Life: Six months in CTL container
Recommended Storage Temperature: 0-20°C
Warranty Period: 12 months from date of despatch