Gas sensors
Gas sensors
Product | Description | Life expectancy | Measurement range | Target Gas | Response Time | Output |
---|---|---|---|---|---|---|
|
HCN 3E 30 F City Technology - Electrochemical Cell Hydrogen cyanide HCN 3 Electrode sensor with organic electrolyte. |
Life expectancy
> 18 months
|
Measurement range
0 – 30 ppm
|
Target Gas
Hydrogen cyanide
|
Response Time
< 50 seconds (T90)
|
Output
60 ± 15 nA/ppm
|
|
HCl 3E 30 City Technology - Electrochemical cell for Hydrogen Chloride |
Life expectancy
> 24 months
|
Measurement range
0-30 ppm
|
Target Gas
Hydrogen Chloride
|
Response Time
< 70 seconds (T90)
|
Output
140 ± 60 nA/ppm
|
|
HF 3E 10 SE City Technology (Sensoric) - 3 Electrode sensor for Hydrofluoric Acid (HF) |
Life expectancy
> 18 months
|
Measurement range
0-10 ppm
|
Target Gas
Hydrofluoric acid
|
Response Time
< 90 seconds (T90)
|
Output
300 ± 100 nA/ppm
|
|
MOX-1 City Technology - Electrochemical Cell for Oxygen O2 |
Life expectancy
1.5 x 106 % O2 hours at 20°C
|
Measurement range
0-1500 mBar O2
|
Target Gas
Oxygen
|
Response Time
< 15 seconds (T90)
|
Output
9 - 13 mV in 210 mBar O2
|
|
MOX-20 City Technology - Electrochemical Cell for Oxygen O2 - Molex connector, M16 thread |
Life expectancy
276,000 % O2 hrs
|
Measurement range
0-1500mBar
|
Target Gas
Oxygen
|
Response Time
T10-90 <750ms at flow rate 0.5L/min (T90 flow dependant)
|
Output
0.8 - 1.25V in Air
|
|
NH3 3E 100 City Technology - 3 Electrode Electrochemical Cell for Ammonia with organic electrolyte |
Life expectancy
> 18 months
|
Measurement range
0-100 ppm
|
Target Gas
Ammonia
|
Response Time
< 120 seconds (T90)
|
Output
90 ± 40 nA/ppm
|
|
NH3 3E 100 SE City Technology - 3 Electrode Electrochemical Cell for Ammonia |
Life expectancy
> 24 months
|
Measurement range
0-100 ppm
|
Target Gas
Ammonia
|
Response Time
< 60 seconds (T90)
|
Output
130 ± 30 nA/ppm
|
|
NH3 3E 1000 City Technology - 3 Electrode Electrochemical Cell with organic electrolyte for Ammonia |
Life expectancy
> 18 months
|
Measurement range
0-1000 ppm
|
Target Gas
Ammonia
|
Response Time
< 120 seconds (T90)
|
Output
6 ± 3 nA/ppm
|
|
NH3 3E 1000 SE City Technology - 3 Electrode Electrochemical Cell for Ammonia |
Life expectancy
> 24 months
|
Measurement range
0-1000 ppm
|
Target Gas
Ammonia
|
Response Time
< 90 seconds (T90)
|
Output
8 ± 4 nA/ppm
|
|
NH3 3E 500 SE City Technology - 3 Electrode Electrochemical Cell for Ammonia |
Life expectancy
> 24 months
|
Measurement range
0-500 ppm
|
Target Gas
Ammonia
|
Response Time
< 90 seconds (T90)
|
Output
35 ± 15 nA/ppm
|