Contact us
NH3 3E 1000
Product code
NH3 3E 1000
Manufacturer
Amperometric 3 electrode sensor cell
Measuring Range: 0–1000 ppm
Sensitivity Range: 6 nA/ppm ± 3 nA/ppm
Zero Current at 20°C: <± 40 nA
Resolution at 20°C: <15 ppm
Bias Potential: 0 mV
Linearity: <5% full scale
Response Time at 20°C:
t50: <20 s calculated from 5 min. exposure time
t90: <120 s calculated from 5 min. exposure time
Long Term Sensitivity Drift: <10% per 6 months
Temperature Range: -40°C to +40°C
Humidity Range: 15–90% r.H, non–condensing
Effect of Humidity:
an abrupt change of r.H. will cause a short term drift of zero reading
Sensor Life Expectancy: > 18 months in air
Life expectancy
> 18 months
Measurement range
0-1000 ppm
Target Gas
Ammonia
Response Time
< 120 seconds (T90)
Output
6 ± 3 nA/ppm
Scheda tecnica207.79 KB