Contact us
NH3 3E 500 SE
Product code
NH3 3E 500 SE
Manufacturer
Amperometric 3 electrode sensor cell
Measuring Range: 0–500 ppm
Sensitivity Range: 35nA/ppm ± 15nA/ppm
Zero Current at 20°C: <± 100nA, typically 40nA
Bias Potential: 0 mV
Linearity: <10% full scale
Response Time at 20°C:
t50: <30 s calculated from 5 min. exposure time
t90: <90 s calculated from 5 min. exposure time
Long Term Sensitivity Drift: <5% per 6 months
Temperature Range: -20°C to +40°C
Humidity Range: 15–90% r.H, non–condensing
Effect of Humidity:
no effect on zero reading during abrupt changes of RH
Expected Operating Life: > 24 months in air
Life expectancy
> 24 months
Measurement range
0-500 ppm
Target Gas
Ammonia
Response Time
< 90 seconds (T90)
Output
35 ± 15 nA/ppm
Scheda tecnica69.68 KB