Gas sensors
Gas sensors
Product | Description | Accuracy | Power Supply | Dimension | Measurement range | Humidity range | Target Gas | Operating temperature | Output | Working temperature |
---|---|---|---|---|---|---|---|---|---|---|
|
H-250-12V NDIR module for the measure of high concentration of Carbon Dioxide (CO2) |
Accuracy
± 300ppm ± 3% of reading
|
Power Supply
12.0 Vdc
|
Dimension
50 x 69 x 20 mm
|
Measurement range
0-5%
0-10%
0-15%
0-20%
0-25%
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Carbon dioxide
|
Operating temperature
-10°C / +60°C
|
Output
PWM
I2C
UART
Analog (0.5V - 4.5V)
|
|
|
H-250-3V NDIR module for the measure of high concentration of Carbon Dioxide (CO2) |
Accuracy
± 300ppm ± 3% of reading
|
Power Supply
3.3 Vdc
|
Dimension
32.5 x 38 x 19.1 mm
|
Measurement range
0-5%
0-10%
0-15%
0-20%
0-25%
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Carbon dioxide
|
Operating temperature
-10°C / +60°C
|
Output
I2C
PWM
UART
Analog (0.5V - 3.0V)
|
|
|
H-250-5V NDIR module for the measure of high concentration of Carbon Dioxide (CO2) |
Accuracy
± 300ppm ± 3% of reading
|
Power Supply
5.0 Vdc
|
Dimension
32.5 x 38 x 19.1 mm
|
Measurement range
0-5%
0-10%
0-15%
0-20%
0-25%
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Carbon dioxide
|
Operating temperature
-10°C / +60°C
|
Output
I2C
PWM
UART
Analog (0.5V - 4.5V)
|
|
|
S-110 NDIR module for the measure of CO2. With its compact size it is particularly suitable for several applications. |
Accuracy
± 30ppm ± 3% of reading
|
Power Supply
5.0 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Measurement range
0-2000 ppm
0-3000 ppm
0-5000 ppm
0-10000 ppm
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Carbon dioxide
|
Operating temperature
-10°C / +60°C
|
Output
Analog (0.5V - 4.5V)
I2C
UART
|
|
|
S-110H NDIR module for the measure of CO2. |
Accuracy
± 50ppm ± 3% of reading
|
Power Supply
12.0 Vdc
|
Dimension
39 x 32 x 13.1 mm
|
Measurement range
0-2000 ppm
0-3000 ppm
0-5000 ppm
0-10000 ppm
|
Humidity range
0-99% RH
0-95% RH
|
Target Gas
Carbon dioxide
|
Operating temperature
-10°C / +60°C
|
Output
UART
I2C
PWM
Analog (0.5V - 4.5V)
|
|
|
S-300 NDIR module for the measure of CO2. With its compact size it is particularly suitable for several applications. |
Accuracy
± 30ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Power Supply
5.0 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Measurement range
0-2000 ppm
0-3000 ppm
0-5000 ppm
0-10000 ppm
0-2%
0-3%
0-5%
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Carbon dioxide
|
Output
PWM
UART
I2C
Analog (0.5V - 4.5V)
|
Working temperature
-10°C / 60°C
|
|
|
S-300-3V NDIR module for the measure of CO2. With its compact size it is particularly suitable for several applications. |
Accuracy
± 30ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Power Supply
3.3 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Measurement range
0-2000 ppm
0-3000 ppm
0-5000 ppm
0-10000 ppm
0-2%
0-3%
0-5%
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Carbon dioxide
|
Operating temperature
-10°C / +60°C
|
Output
UART
I2C
PWM
Analog (0.5V - 3.0V)
|
|
|
T-110 As world’s smallest CO2 sensor module, T-110 Series are developed as residential indoor air-quality monitoring application |
Accuracy
± 50ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Power Supply
5.0 Vdc
|
Dimension
19 x 29.3 x 8.5 mm
|
Measurement range
400-2000 ppm
400-3000 ppm
400-5000 ppm
400-10000 ppm
0.04-10%
0.04-5%
0.04-3%
0.04-2%
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Carbon dioxide
|
Output
I2C
UART
Analog (0.5V - 4.5V)
PWM
|
Working temperature
0°C / 50°C
|
|
|
T-110-3V As world’s smallest CO2 sensor module, T-110 Series are developed as residential indoor air-quality monitoring application. |
Accuracy
± 50ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Power Supply
3.3 Vdc
|
Dimension
19 x 29.3 x 8.5 mm
|
Measurement range
400-2000 ppm
400-3000 ppm
400-5000 ppm
400-10000 ppm
0-2%
0-3%
0-5%
0-10%
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Carbon dioxide
|
Operating temperature
0°C / +50°C
|
Output
I2C
UART
Analog (0.5V - 3.0V)
PWM
|
|
|
T-200 NDIR module for CO2 measurement |
Accuracy
± 50ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Power Supply
5.0 Vdc
|
Dimension
19.4 x 30 x10.3 mm
|
Measurement range
400-2000 ppm
400-3000 ppm
400-5000 ppm
400-10000 ppm
0.04-2%
0.04-3%
0.04-5%
0.04-10%
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Anidride Carbonica
|
Operating temperature
-20°C / +60°C
|
Output
I2C
UART
Analogica (0.5V - 4.5V)
PWM
|