MEASUREMENT
Operating Principle: 2-electrode electrochemical
Measurement Range: 0-200 ppm CO
Maximum Overload: 500 ppm CO
Filter: To remove SO2 and H2S
Sensitivity: 0.10 ± 0.02 μA/ppm
Resolution: 1 ppm
Response Time (T90): <40 seconds
Baseline Offset (clean air): -1 to +3 ppm equivalent
Zero Shift (+20°C to +40°C): 9 ppm equivalent
Repeatability: 1% of signal
Linearity: Linear
ELECTRICAL
Recommended Load Resistor: 10 Ω
Bias Voltage: Not Required
MECHANICAL
Weight: 22 g
Orientation: Any
ENVIRONMENTAL
Operating Temperature Range: -20°C to +50°C
Recommended Storage Temp: 0°C to 20°C
Operating Pressure Range: Atmospheric ± 10%
Operating Humidity Range: 15 - 90% RH non-condensing
LIFETIME
Long Term Sensitivity Drift: <5% signal loss/year
Expected Operating Life: Two years in air
Storage Life: 6 months in CTL container
2EF
Product code
2EF
Manufacturer
Life expectancy
> 24 months
Measurement range
0-200 ppm
Target Gas
Carbon Monoxide
Response Time
< 40 seconds (T90)
Output
100 ± 20 nA/ppm