Gas sensors
Gas sensors
Product | Description | Life expectancy | Output | Measurement range | Target Gas | Response Time | Compatible analyzers | Accuracy | Power Supply | Dimension | Humidity range | Operating temperature |
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
B2H6 3E 1 LT City Technology - Electrochemical cell for Diborane |
Life expectancy
> 24 months
|
Output
2.2 ± 0.5 μA/ppm
|
Measurement range
0-1 ppm
|
Target Gas
Diborane
|
Response Time
< 30 seconds (T90)
|
||||||
|
BBF001CK Coalescent filter for exhaust gas analysers. Suitable for Brain Bee and Motorscan analyzers. |
Compatible analyzers
Brain Bee
|
||||||||||
|
BBF002CA Active carbons filter for exhaust gas analysers |
Compatible analyzers
Compatible with every analyzer
|
||||||||||
|
C/N City Technology - Electrochemical Cell for Oxygen O2 |
Life expectancy
> 9 months
|
Output
1.10 ± 0.17 mA in Air
|
Measurement range
0-25% Oxygen
|
Target Gas
Oxygen
|
Response Time
< 20 seconds (T95)
|
||||||
|
C/Y City Technology - Electrochemical Cell for Oxygen for general purpose |
Life expectancy
> 12 months
|
Output
0.80 ± 0.12 mA in air
|
Measurement range
0-25% Oxygen
|
Target Gas
Oxygen
|
Response Time
<10 seconds (T95)
|
||||||
|
C2H4-CD300 Transmitter board with NDIR sensor for Ethylene (C2H4) |
Output
4-20 mA
2-10 Vdc
0-10 Vdc
0-20 mA
|
Measurement range
0-100% LEL
0-27000 ppm
|
Target Gas
Ethylene
|
Accuracy
± 3% F.S.
|
Power Supply
24 VDC
|
Dimension
123 x 70 x 43 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-20°C / +50°C
|
|||
|
C2H4-D3 NDIR module for the measure of Ethylene (C2H4) |
Output
I2C
UART
Analog (0.5V - 4.5V)
PWM
|
Measurement range
0-27000 ppm
|
Target Gas
Ethylene
|
Accuracy
± 3% F.S.
|
Power Supply
5.0 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-20°C / +50°C
|
|||
|
C2H4-D3-3V NDIR module for the measure of Ethylene (C2H4) |
Output
I2C
UART
Analog (0.5V - 3.0V)
PWM
|
Measurement range
0-27000 ppm
|
Target Gas
Ethylene
|
Accuracy
± 3% F.S.
|
Power Supply
3.3 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-20°C / +50°C
|
|||
|
C2H4-LD-3V NDIR module for the measure of Ethylene |
Output
I2C
UART
Analog (0.5V - 3.0V)
|
Measurement range
0-2000 ppm
0-27000 ppm
|
Target Gas
Ethylene
|
Accuracy
± 3% F.S.
|
Power Supply
3.3 Vdc
|
Dimension
40 x 38 x 18.5 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-20°C / +50°C
|
|||
|
C2H4-LF-3V NDIR module for the measure of Ethylene. |
Output
I2C
UART
Analog (0.5V - 3.0V)
|
Measurement range
0-2000 ppm
0-27000 ppm
|
Target Gas
Ethylene
|
Accuracy
± 3% F.S.
|
Power Supply
3.3 Vdc
|
Dimension
40 x 38 x 18.5 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-20°C / +50°C
|