Contact us
O3 3E 1 F
Product code
O3 3E 1 F
Manufacturer
Measuring Range: 0–1 ppm
Sensitivity Range: 450 +/- 150 nA/ppm (negative signal)
Zero Current at 20°C: < ± 10 nA
Resolution at 20°C: < 0.03 ppm
Bias Potential: 0 mV
Linearity: < 10% full scale
Response Time at 20°C:
t50 < 15 s calculated from 3 min. exposure time1)
t90 < 60 s calculated from 3 min. exposure time1)
Long Term Sensitivity Drift: < 5% per month
Temperature Range: -20°C to +40°C
Humidity Range: 15–90% r.H., non–condensing
Effect of Humidity: abrupt changes will cause a short term drift
Sensor Life Expectancy: > 18 months
Life expectancy
> 18 months
Measurement range
0-1 ppm
Target Gas
Ozone
Response Time
< 60 seconds (T90)
Output
450 ± 150 nA/ppm
O3 3E 1 F Datasheet200.3 KB