Product | Description | Measurement range | Target Gas | Response Time | Output | Life expectancy | Accuracy | Power Supply | Dimension | Humidity range | Operating temperature |
---|---|---|---|---|---|---|---|---|---|---|---|
|
CMM5042 The CMM5042 carbon monoxide sensor module is a new unit which utilizes TGS5042, Figaro's electrochemical CO sensor, a widely used model for residential and commercial CO detectors with excellent durability and long term stability. |
Measurement range
0-800 ppm
|
Target Gas
Carbon Monoxide
|
Response Time
< 60 seconds (T90)
|
Output
0-2 VDC
|
||||||
|
CO 3E 300 City Technology - Electrochemical Cell for Carbon Monoxide |
Measurement range
0-500 ppm
|
Target Gas
Carbon Monoxide
|
Response Time
< 40 seconds (T90)
|
Output
70 ± 20 nA/ppm
|
Life expectancy
> 4 years
|
|||||
|
COCl2 3E 1 City Technology - Electrochemical Cell for Phosgene |
Measurement range
0-1 ppm
|
Target Gas
Phosgene
|
Response Time
< 120 seconds (T90)
|
Output
650 ± 150 nA/ppm
|
Life expectancy
> 12 months
|
|||||
|
Cl2 3E 10 City Technology - Electrochemical Cell for Chlorine |
Measurement range
0-10 ppm
|
Target Gas
Chlorine
|
Response Time
< 60 seconds (T90)
|
Output
450 ± 200 nA/ppm
|
Life expectancy
> 4 years
|
|||||
|
Cl2 3E 50 City Technology - Electrochemical Cell for Chlorine |
Measurement range
0-50 ppm
|
Target Gas
Chlorine
|
Response Time
< 60 seconds (T90)
|
Output
450 ± 200 nA/ppm
|
Life expectancy
> 24 months
|
|||||
|
D-300 NDIR module for the measure of CO2 |
Measurement range
0-2000 ppm
0-3000 ppm
0-5000 ppm
0-10000 ppm
0-2%
0-3%
0-5%
0-7%
0-10%
|
Target Gas
Carbon dioxide
|
Output
I2C
UART
Analog (0.5V - 4.5V)
PWM
|
Accuracy
± 30ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Power Supply
5.0 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-20°C / +50°C
|
||
|
D-300-3V NDIR module for the measure of CO2 |
Measurement range
0-2000 ppm
0-3000 ppm
0-5000 ppm
0-10000 ppm
0-2%
0-3%
0-5%
0-7%
0-10%
|
Target Gas
Anidride Carbonica
|
Output
I2C
UART
Analog (0.5V - 3.0V)
PWM
|
Accuracy
± 300ppm ± 3% of reading
± 30ppm ± 3% of reading
|
Power Supply
3.3 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-20°C / +50°C
|
||
|
D-400 NDIR dual beam module for the measure of CO2. With its compact size it is particularly suitable for several applications. |
Measurement range
0-2000 ppm
0-3000 ppm
0-5000 ppm
0-10000 ppm
0-2%
0-3%
0-5%
|
Target Gas
Carbon dioxide
|
Output
I2C
UART
Analog (0.5V - 3.0V)
PWM
|
Accuracy
± 30ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Power Supply
5.0 Vdc
|
Dimension
50 x 69 x 26 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-20°C / +50°C
|
||
|
D-400-3V Modulo dual beam NDIR per la misura della CO2. Grazie al suo formato compatto risulta adatto per svariate applicazioni dall'HVAC alle serre. |
Measurement range
0-2000 ppm
0-3000 ppm
0-5000 ppm
0-10000 ppm
0-2%
0-3%
0-5%
|
Target Gas
Carbon dioxide
|
Output
I2C
PWM
UART
Analog (0.5V - 3.0V)
|
Accuracy
± 30ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Power Supply
3.3 Vdc
|
Dimension
50 x 69 x 26 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-20°C / +50°C
|
||
|
DUT-1000 Transmitter and NDIR sensor for measuring CO2 concentration in ducts. |
Measurement range
0-2000 ppm
0-3000 ppm
0-5000 ppm
0-10000 ppm
0-2%
0-3%
0-5%
|
Target Gas
Carbon dioxide
|
Output
4-20 mA
2-10 Vdc
RS485
Relay
|
Accuracy
± 50ppm ± 3% of reading
|
Power Supply
24V AC/DC
|
Dimension
85 x 115 x 45 mm, 250 x 40 mm
|
Humidity range
0-99% RH
|
Operating temperature
0°C / 50°C
|