Gas sensors
Gas sensors
Product | Description | Accuracy | Power Supply | Dimension | Measurement range | Humidity range | Target Gas | Operating temperature | Output | Life expectancy | Response Time | Application field | Heater consumption |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
T-300A-3V Miniature NDIR module for the measure of CO2. Designed for customers in residential buildings, offices, or cabin of vehicles, or so. |
Accuracy
± 25ppm ± 5% of reading
|
Power Supply
3.3 Vdc
|
Dimension
19 x 31 x 7.9 mm
|
Measurement range
400-2000 ppm
400-3000 ppm
400-5000 ppm
400-10000 ppm
|
Humidity range
0-95% RH
|
Target Gas
Carbon dioxide
|
Operating temperature
-10°C / +60°C
|
Output
I2C
UART
PWM
|
||||
|
T3SH City Technology 3 electrode sensor with standard 4-20mA board for Hydrogen sulfide (H2S) |
Target Gas
Sulfur Dioxide
|
Output
4-20 mA
|
Life expectancy
> 24 months
|
Response Time
< 15 seconds (T90)
|
||||||||
|
TEC-OXY-D0-ZZ Oxygen measurement module in various ranges between 10ppm and 96% based on zirconium oxide sensor. |
Power Supply
12 - 24 Vdc
|
Measurement range
10-1.000 ppm
0.05-1 %
0.05-2 %
0.05-3 %
0.1-25 %
0.1-95 %
0.1-96 %
|
Target Gas
Oxygen
|
Output
0-10V, linear
4-20 mA, linear
|
||||||||
|
TEC-OXY-D1-ZZ Oxygen measurement module in various ranges between 10ppm and 96% based on zirconium oxide sensor |
Power Supply
12 - 24 Vdc
|
Measurement range
10-1.000 ppm
0.05-1 %
0.05-2 %
0.05-3 %
0.1-25 %
0.1-95 %
0.1-96 %
|
Target Gas
Oxygen
|
Output
4-20 mA, linear
0-10V, linear
RS485
Relay
|
||||||||
|
TEC-OXY-D2-ZZ Oxygen measurement module in various ranges between 10ppm and 96% based on zirconium oxide sensor. |
Power Supply
12 - 24 Vdc
|
Measurement range
10-1.000 ppm
0.05-1 %
0.05-2 %
0.05-3 %
0.1-25 %
0.1-95 %
0.1-96 %
|
Target Gas
Oxygen
|
Output
4-20 mA, linear
0-10V, linear
RS485
USB
RS232
Relay
|
||||||||
|
TEC-OXY-D3-ZZ Oxygen measurement module with display in various ranges between 10ppm and 96% based on zirconium oxide sensor. |
Power Supply
12 - 24 Vdc
|
Measurement range
10-1.000 ppm
0.05-1 %
0.05-2 %
0.05-3 %
0.1-25 %
0.1-95 %
0.1-96 %
|
Target Gas
Oxygen
|
Output
4-20 mA, linear
0-10V, linear
RS485
USB
RS232
Relay
|
||||||||
|
TEC-OXY-METAL-ZZ Module with aluminum housing for the oxygen measurement in different ranges, from 10ppm up to 96%, based on zirconium oxide technology. The aluminum housing and its mechanical configuration allow an easy connection to the system. |
Power Supply
12 - 24 Vdc
|
Measurement range
10-1.000 ppm
0.05-1 %
0.05-2 %
0.05-3 %
0.05-5%
0.1-25 %
0.1-96 %
|
Target Gas
Oxygen
|
Output
4-20 mA
0-10 Vdc
RS485
|
||||||||
|
TEC-OXY-S0-ZZ Oxygen measurement module in various ranges between 10ppm and 96% based on zirconium oxide sensor |
Power Supply
12 - 24 Vdc
|
Measurement range
10-1.000 ppm
0.05-1 %
0.05-2 %
0.05-3 %
0.1-25 %
0.1-95 %
0.1-96 %
|
Target Gas
Oxygen
|
Output
0-10V, linear
4-20 mA, linear
|
||||||||
|
TEC-OXY-S1-ZZ Oxygen measurement module in various ranges between 10ppm and 96% based on zirconium oxide sensor |
Power Supply
12 - 24 Vdc
|
Measurement range
10-1.000 ppm
0.05-1 %
0.05-2 %
0.05-3 %
0.1-25 %
0.1-95 %
0.1-96 %
|
Target Gas
Oxygen
|
Output
4-20 mA, linear
0-10V, linear
RS485
Relay
|
||||||||
|
TGS8410 TG 8410 methane gas sensor, based on MEMS technology. |
Measurement range
1-25% LEL
|
Target Gas
Methane
|
Application field
Domestic
|
Heater consumption
0.087 mW (medium)
|