Gas sensors
Gas sensors
Product | Description | Life expectancy | Output | Measurement range | Target Gas | Response Time |
---|---|---|---|---|---|---|
|
4PH Fast City Technology - Electrochemical cell for Phosphine |
Life expectancy
> 24 months
|
Output
1.7 ± 0.3 μA/ppm
|
Measurement range
0-5 ppm
|
Target Gas
Phosphine
|
Response Time
< 60 seconds (T90)
|
|
5F City Technology - Electrochemical Cell for Carbon Monoxide |
Life expectancy
> 3 years
|
Output
30 ± 6 nA/ppm
|
Measurement range
0-4000 ppm
|
Target Gas
Carbon Monoxide
|
Response Time
< 40 seconds (T90)
|
|
5FO City Technology - Electrochemical Cell for Oxygen |
Life expectancy
> 24 months
|
Output
410 ± 50 μA/ppm
|
Measurement range
0-25% Oxygen
|
Target Gas
Oxygen
|
Response Time
< 20 seconds (T95)
|
|
5MF City Technology - Electrochemical Cell for Carbon Monoxide |
Life expectancy
> 3 years
|
Output
10 ± 4 nA/ppm
|
Measurement range
0-40.000 ppm
|
Target Gas
Carbon Monoxide
|
Response Time
< 40 seconds (T90)
|
|
5ND City Technology - Electrochemical Cell for Nitrogen Dioxide |
Life expectancy
> 24 months
|
Output
370 ± 70 nA/ppm
|
Measurement range
0-200 ppm
|
Target Gas
Nitrogen dioxide
|
Response Time
< 60 seconds (T90)
|
|
5NF City Technology - Electrochemical Cell for Nitric Oxide |
Life expectancy
> 3 years
|
Output
100 ± 20 nA/ppm
|
Measurement range
0-1000 ppm
|
Target Gas
Nitric Oxide
|
Response Time
< 30 seconds (T90)
|
|
5OxLL City Technology - Electrochemical Cell for Oxygen |
Life expectancy
> 7 years
|
Output
80 - 130 μA in air
|
Measurement range
0-25% Oxygen
|
Target Gas
Oxygen
|
Response Time
< 15 seconds (T90)
|
|
5SF City Technology - Electrochemical Cell for Sulfur Dioxide |
Life expectancy
> 24 months
|
Output
100 ± 20 nA/ppm
|
Measurement range
0-2000 ppm
|
Target Gas
Sulfur Dioxide
|
Response Time
< 30 seconds (T90)
|
|
5SFF City Technology - Electrochemical Cell for Sulfur Dioxide |
Life expectancy
> 24 months
|
Output
100 ± 20 nA/ppm
|
Measurement range
0-2000 ppm
|
Target Gas
Sulfur Dioxide
|
Response Time
< 40 seconds (T90)
|
|
7E City Technology - Electrochemical Cell for Carbon Monoxide |
Life expectancy
> 3 years
|
Output
100 ± 20 nA/ppm
|
Measurement range
0-1000 ppm
|
Target Gas
Carbon Monoxide
|
Response Time
< 25 seconds (T90)
|