5F

5F
5F
Product code
5F
Manufacturer
City Technology - Electrochemical Cell for Carbon Monoxide

Nominal Range: 0-4000ppm
Maximum Overload: 20 000ppm
Fixed Filter Life: > 200,000ppm hours (1000ppm NO @ 500ml/min)
Expected Operating Life: Three years in air
Output Signal: 0.030 ± 0.006 μA/ppm
Resolution: 1ppm
Temperature Range: -20°C to +50°C
Pressure Range: Atmospheric ± 10%
Pressure Coefficient: 0.007 ± 0.003 %signal/mBar
T90 Response Time: <40 seconds
Relative Humidity Range: 15 to 90% non-condensing
Typical Baseline Range (pure air): -10 to +5ppm equivalent
Maximum Zero Shift (+20°C to +40°C): -10ppm equivalent
Long Term Output Drift: <2% signal loss/month
Recommended Load Resistor: 10Ω
Bias Voltage: Not required
Repeatability: 1% of signal
Output Linearity: Linear
Colour Coding: Red

Life expectancy
> 3 years
Measurement range
0-4000 ppm
Target Gas
Carbon Monoxide
Response Time
< 40 seconds (T90)
Output
30 ± 6 nA/ppm
Contact us

Vuoi una quotazione o hai bisogno di informazioni?

I have read and accepted the information relating to the Processing of Personal Data pursuant to EU Regulation 2016/679 articles 13 and 14 * Privacy information