A7EF

A7EF
A7EF
Product code
A7EF
Manufacturer
City Technology - Electrochemical Cell for Carbon Monoxide

MEASUREMENT
Operating Principle
: 4-electrode electrochemical
Measurement Range: 0-1000 ppm CO
Maximum Overload: 2000 ppm CO
Filter: To remove H2S
Auxillary Electrode: To compensate for hydrogen cross interference
Sensitivity: 0.10 ± 0.02 μA/ppm
Response Time (T90): <35 seconds at 20°C
Baseline Offset (clean air): -2 to +15 ppm CO equivalent
Resolution: 0.5 ppm (when used with recommended electronics)
Repeatability: 1% of signal
Linearity: Linear

ELECTRICAL
Recommended Load Resistor
: 10 Ω
Bias Voltage: 0 or +250 mV

MECHANICAL
Weight
: 25 g
Housing Material:

  • Cap: Polycarbonate
  • Body: ABS

Orientation: Any

ENVIRONMENTAL
Operating Temperature Range: -20°C to +50°C
Recommended Storage Temp: 0°C to 20°C
Operating Pressure Range: Atmospheric ± 10%
Pressure Coefficient: 0.02% signal / mBar
Operating Humidity Range: 15 - 90% RH non-condensing

LIFETIME
Long Term Sensitivity Drift
: < 5% signal loss/year
Expected Operating Life: Three years in air
Storage Life: 6 months in CTL container

Life expectancy
> 3 years
Measurement range
0-1000 ppm
Target Gas
Carbon Monoxide
Response Time
< 35 seconds (T90)
Output
100 ± 20 nA/ppm
Datasheet399.7 KB
Contact us

Vuoi una quotazione o hai bisogno di informazioni?

I have read and accepted the information relating to the Processing of Personal Data pursuant to EU Regulation 2016/679 articles 13 and 14 * Privacy information