MEASUREMENT
Operating Principle: 3-electrode electrochemical
Nominal Range: 0 to 200 ppm NO2
Maximum Overload: 1000 ppm NO
Filter: None
Sensitivity: 0.37 ± 0.07 mA/ppm
Response Time (T90): < 60 seconds
Baseline Offset (clean air):± 0.5 ppm equivalent
Baseline Shift (+20°C to +40°C): -1 ppm equivalent
Repeatability: 2% of signal
Linearity: Linear
ELECTRICAL
Resolution: 0.5 ppm
Recommended Load Resistor: 33 Ω
Bias Voltage: Not Required
MECHANICAL
Weight: 10 g nominal
Orientation Sensitivity: None
ENVIRONMENTAL
Operating Temperature Range: -20°C to +50°C
Pressure Coefficient: 0.037 %signal/mBar
Operating Pressure Range: Atmospheric ± 10%
Operating Humidity Range: 15 - 90% rH
LIFETIME
Long Term Sensitivity Drift: <2% signal loss per month
Expected Operating Life: Two years in air
Recommended Storage Temp: 0°C to +20°C in sealed container
5ND
Product code
5ND
Manufacturer
Life expectancy
> 24 months
Measurement range
0-200 ppm
Target Gas
Nitrogen dioxide
Response Time
< 60 seconds (T90)
Output
370 ± 70 nA/ppm
Datasheet367.92 KB