CO 3E 300

CO 3E 300
CO 3E 300
Product code
CO 3E 300
Manufacturer
City Technology - Electrochemical Cell for Carbon Monoxide

Measuring Range: 0-500 ppm
Sensitivity Range: 70 nA/ppm ± 20 nA/ppm
Zero Current at 20°C: < 150 nA
Resolution at 20°C: < 3 ppm
Bias Potential: 0 mV
Linearity: < 5% full scale

Response Time at 20°C:

  • t50 < 10 s calculated from 2 min. exposure time
  • t90 < 30 s calculated from 2 min. exposure time

Long Term Sensitivity Drift: < 10% per 6 months

Operation Conditions
Temperature Range: -40°C to + 50°C
Humidity Range: 15-90 % r.H., non-condensing

Effect of Humidity: no effect on base line shift, longer exposure to dry gas might decrease the sensitivity

Sensor Life Expectancy: > 4 years
Warranty: 24 months

Life expectancy
> 4 years
Measurement range
0-500 ppm
Target Gas
Carbon Monoxide
Response Time
< 40 seconds (T90)
Output
70 ± 20 nA/ppm
Datasheet213.35 KB
Contact us

Vuoi una quotazione o hai bisogno di informazioni?

I have read and accepted the information relating to the Processing of Personal Data pursuant to EU Regulation 2016/679 articles 13 and 14 * Privacy information