Contact us
S+4 2ECOH
Product code
S+4 2ECOH
Manufacturer
Electrochemical cell for carbon monoxide with low idrogen sensitivity.
Measurement Range 0 – 200 ppm
Output Signal 175 ± 50 nA / ppm
Linearity: within ± 5%
Repeatability <± 5%
Response time, T90 <30 s
Maximum Overload 300 ppm
Long-term Output Drift <5% per annum
Recommended Load Resistor 10 ohms
Warranty 2 years from the date of dispatch
Resolution (Electronics dependent) < 1 ppm typical
Life expectancy
> 2 years
Measurement range
0-200 ppm
Target Gas
Carbon Monoxide
Response Time
< 30 seconds (T90)
Output
175 ± 50 nA/ppm
Datasheet240.65 KB
S+4 2ECOH Recommended Circuit18.74 KB