Gas sensors
Gas sensors
Product | Description | Power Supply | Measurement range | Target Gas | Output | Application field | Heater consumption |
---|---|---|---|---|---|---|---|
|
TEC-OXY-D0-ZZ Oxygen measurement module in various ranges between 10ppm and 96% based on zirconium oxide sensor. |
Power Supply
12 - 24 Vdc
|
Measurement range
10-1.000 ppm
0.05-1 %
0.05-2 %
0.05-3 %
0.1-25 %
0.1-95 %
0.1-96 %
|
Target Gas
Oxygen
|
Output
0-10V, linear
4-20 mA, linear
|
||
|
TEC-OXY-D1-ZZ Oxygen measurement module in various ranges between 10ppm and 96% based on zirconium oxide sensor |
Power Supply
12 - 24 Vdc
|
Measurement range
10-1.000 ppm
0.05-1 %
0.05-2 %
0.05-3 %
0.1-25 %
0.1-95 %
0.1-96 %
|
Target Gas
Oxygen
|
Output
4-20 mA, linear
0-10V, linear
RS485
Relay
|
||
|
TEC-OXY-D2-ZZ Oxygen measurement module in various ranges between 10ppm and 96% based on zirconium oxide sensor. |
Power Supply
12 - 24 Vdc
|
Measurement range
10-1.000 ppm
0.05-1 %
0.05-2 %
0.05-3 %
0.1-25 %
0.1-95 %
0.1-96 %
|
Target Gas
Oxygen
|
Output
4-20 mA, linear
0-10V, linear
RS485
USB
RS232
Relay
|
||
|
TEC-OXY-D3-ZZ Oxygen measurement module with display in various ranges between 10ppm and 96% based on zirconium oxide sensor. |
Power Supply
12 - 24 Vdc
|
Measurement range
10-1.000 ppm
0.05-1 %
0.05-2 %
0.05-3 %
0.1-25 %
0.1-95 %
0.1-96 %
|
Target Gas
Oxygen
|
Output
4-20 mA, linear
0-10V, linear
RS485
USB
RS232
Relay
|
||
|
TEC-OXY-METAL-ZZ Module with aluminum housing for the oxygen measurement in different ranges, from 10ppm up to 96%, based on zirconium oxide technology. The aluminum housing and its mechanical configuration allow an easy connection to the system. |
Power Supply
12 - 24 Vdc
|
Measurement range
10-1.000 ppm
0.05-1 %
0.05-2 %
0.05-3 %
0.05-5%
0.1-25 %
0.1-96 %
|
Target Gas
Oxygen
|
Output
4-20 mA
0-10 Vdc
RS485
|
||
|
TEC-OXY-S0-ZZ Oxygen measurement module in various ranges between 10ppm and 96% based on zirconium oxide sensor |
Power Supply
12 - 24 Vdc
|
Measurement range
10-1.000 ppm
0.05-1 %
0.05-2 %
0.05-3 %
0.1-25 %
0.1-95 %
0.1-96 %
|
Target Gas
Oxygen
|
Output
0-10V, linear
4-20 mA, linear
|
||
|
TEC-OXY-S1-ZZ Oxygen measurement module in various ranges between 10ppm and 96% based on zirconium oxide sensor |
Power Supply
12 - 24 Vdc
|
Measurement range
10-1.000 ppm
0.05-1 %
0.05-2 %
0.05-3 %
0.1-25 %
0.1-95 %
0.1-96 %
|
Target Gas
Oxygen
|
Output
4-20 mA, linear
0-10V, linear
RS485
Relay
|
||
|
TGS8410 TG 8410 methane gas sensor, based on MEMS technology. |
Measurement range
1-25% LEL
|
Target Gas
Methane
|
Application field
Domestic
|
Heater consumption
0.087 mW (medium)
|
||
|
TGS1820 TGS1820 is a hot wire semiconductor type gas sensor. TGS1820 has high sensitivity to acetone with small interference from ethanol and hydrogen. This feature makes the sensor ideal for breath acetone analysis |
Measurement range
1-20 ppm
|
Target Gas
Acetone
|
Heater consumption
125 mW
|
|||
|
TGS2600 The TGS 2600 has high sensitivity to low concentrations of gaseous air contaminants such as hydrogen and carbon monoxide which exist in cigarette smoke. The sensor can detect hydrogen at a level of several ppm. |
Measurement range
1-30 ppm H2
|
Target Gas
Air pollutants
|