Gas sensors
Gas sensors
Product | Description | Life expectancy | Measurement range | Target Gas | Response Time | Output | Temperature range | Accuracy | Power Supply | Dimension | Humidity range | Operating temperature | Working temperature |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
AQ3ND City Technology - Electrochemical cell for Nitrogen Dioxide Air Quality cell |
Life expectancy
> 24 months
|
Measurement range
0-1 ppm
|
Target Gas
Nitrogen dioxide
|
Response Time
< 120 seconds (T90)
|
Output
1.029 ± 0.294 mV/ppb
|
|||||||
|
AQ3OZ City Technology - Electrochemical cell for Ozone |
Life expectancy
> 24 months
|
Measurement range
0-1 ppm
|
Target Gas
Ozone
|
Response Time
< 120 seconds (T90)
|
Output
1.20 ± 0.50 mV/ppb
|
|||||||
|
AQ3STF City Technology - Electrochemical cell for Sulfur Dioxide |
Life expectancy
> 24 months
|
Measurement range
0-1 ppm
|
Target Gas
Sulfur Dioxide
|
Response Time
< 40 seconds (T90)
|
Output
0.218 ± 0.044mV/ppb
|
|||||||
|
AQ7CO |
Life expectancy
> 24 months
|
Measurement range
0 ppm CO to 20 ppm CO
|
Target Gas
Carbon Monoxide
|
Response Time
< 60 seconds
|
||||||||
|
AQ7ND |
Life expectancy
> 24 months
|
Measurement range
0 ppm NO2 to 1 ppm NO2
|
Target Gas
Nitrogen dioxide
|
Response Time
< 120 seconds (T90)
|
||||||||
|
AQ7OZ |
Life expectancy
> 24 months
|
Measurement range
0 ppm O3 to 1 ppm O3
|
Target Gas
Ozone
|
Response Time
< 120 seconds (T90)
|
||||||||
|
AQ7SO2 |
Life expectancy
> 24 months
|
Target Gas
Sulfur Dioxide
|
Response Time
< 60 seconds (T90)
|
Temperature range
-30°C to 50°C (55°C intermittent)
|
||||||||
|
AQM-100 AQM-100 series transmitters which can measure gases such as CO2, VOCs, Temperature, Humidity. |
Measurement range
0-10000 ppm
|
Output
RS232
RS485
|
Accuracy
± 30ppm ± 5% of reading
|
Power Supply
12 Vdc
|
Dimension
118 x 74 x 22 mm
|
Humidity range
0-95% RH
|
Operating temperature
0°C / +50°C
|
|||||
|
ASH3-3E-1 City Technology (Sensoric) - 3 Electrode sensor with ionic liquid electrolyte for Arsine (AsH3) |
Life expectancy
> 24 months
|
Measurement range
0-1 ppm
|
Target Gas
Arsine
|
Response Time
< 30 seconds (T90)
|
Output
1.4 ± 0.45 μA/ppm
|
|||||||
|
B-530 NDIR module for the measure of CO2. With its compact size and availability in Moisture proof version too, it is particularly suitable for agricultural field. |
Measurement range
0-2000 ppm
0-3000 ppm
0-5000 ppm
0-10000 ppm
0-5%
|
Target Gas
Carbon dioxide
|
Output
UART
Analog (0.5V - 4.5V)
|
Accuracy
± 30ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Power Supply
12.0 Vdc
|
Dimension
65 x 50 x 20 mm
|
Humidity range
0-95% RH
0-99% RH
|
Working temperature
-20°C / +65°C
|