A3EF

A3EF
A3EF
Product code
A3EF
Manufacturer
City Technology - Electrochemical Cell for Carbon Monoxide

MEASUREMENT
Operating Principle
: 4-electrode electrochemical
Measurement Range: 0-2000 ppm CO
Maximum Overload: 4000 ppm CO
Filter: To remove acid gases
Sensitivity: 0.075 ± 0.025 μA/ppm
Resolution (when using recommended circuitry): 1 ppm
Response Time (T90): <38 seconds
Baseline Offset (clean air): -2 to +17 ppm equivalent
Repeatability: <1% of signal
Linearity: Linear

ELECTRICAL
Recommended Load Resistor
: 10 Ω
Bias Voltage: 0 or +250 mV

MECHANICAL
Weight
: 25 g
Housing Material: Polycarbonate
Orientation: Any

ENVIRONMENTAL
Typical Applications
: Ambient Environmental Monitoring
Operating Temperature Range: -20°C to +50°C
Recommended Storage Temp: 0°C to 20°C
Operating Pressure Range: Atmospheric ± 10%
Pressure Coefficient: 0.02% signal/mBar
Operating Humidity Range: 15 - 90% RH non-condensing

LIFETIME
Long Term Sensitivity Drift
: <2% signal loss/year
Expected Operating Life: Two years in air
Storage Life: 6 months in CTL container

Life expectancy
> 24 months
Measurement range
0-2000 ppm
Target Gas
Carbon Monoxide
Response Time
< 38 seconds (T90)
Output
75 ± 25 nA/ppm
Datasheet309.23 KB
Contact us

Vuoi una quotazione o hai bisogno di informazioni?

I have read and accepted the information relating to the Processing of Personal Data pursuant to EU Regulation 2016/679 articles 13 and 14 * Privacy information