Contact us
A3CO
Product code
A3CO
Manufacturer
Nominal Range: 0-500ppm
Maximum Overload: 1000ppm
Expected Operating Life: Two years
Output Signal: 0.2 ± 0.04 μA/ppm
Resolution: 100ppb
Temperature Range: -20°C to +50°C
Pressure Range: Atmospheric ± 10%
Pressure Coefficient: No data
T90 Response Time: <40 seconds
Relative Humidity Range: 15 to 90% non-condensing
Typical Baseline Range (pure air): 0 to 1ppm equivalent
Maximum Zero Shift (+20°C to +40°C): 2ppm equivalent
Long Term Output Drift: <10% signal loss/year in air
Recommended Load Resistor: 10Ω (see over)
Bias Voltage: Not required
Repeatability: 1% of signal
Output Linearity: Linear
Life expectancy
> 24 months
Measurement range
0-500 ppm
Target Gas
Carbon Monoxide
Response Time
< 40 seconds (T90)
Output
200 ± 40 nA/ppm
Scheda tecnica42.73 KB