7H

7H
7H
Product code
7H
Manufacturer
City Technology - Electrochemical cell for Hydrogen Sulfide

Measuring Range: 0-200 ppm
Sensitivity Range: 0.37 ± 0.07 μA/ppm
Baseline Offset at 20°C: -0.6 to +1.9 ppm H2S equivalent
Bias Potential: not required
Linearity: linear

Response Time: < 35 seconds (t90)

Long Term Sensitivity Drift: < 2% month

Operation Conditions
Temperature Range: -40°C to +50°C
Humidity Range: 15–90% R.H., non–condensing


Sensor Life Expectancy: 2 years in air
Warranty: 6 months

Life expectancy
> 24 months
Output
370 ± 70 nA/ppm
Measurement range
0-200 ppm
Target Gas
Hydrogen sulfide
Response Time
< 35 seconds (T90)
7h.pdf392.83 KB