MEASUREMENT
Operating Principle: 3-electrode electrochemical
Measurement Range: 0-50 ppm H2S
Maximum Overload: 500 ppm H2S
Filter: None
Sensitivity: 1.70 ± 0.30 μA/ppm
Response Time (T90): <30 Seconds
Baseline Offset (clean air): -0.2 to +0.4 ppm H2S equivalent
Maximum Zero Shift (+20°C to +40°C): 0.1 ppm H2S equivalent
Resolution: 0.1 ppm (when used with recommended electronics)
Repeatability: 1% of signal
Linearity: Linear
ELECTRICAL
Recommended Load Resistor: 10 Ω
Bias Voltage: Not required
MECHANICAL
Weight: 22 g
Housing Material: Gap and Body Glass Filled Polypropylene
Orientation: Any
ENVIRONMENTAL
Operating Temperature Range: -40°C to +50°C
Recommended Storage Temp: 0°C to 20°C
Operating Pressure Range: Atmospheric ± 10%
Operating Humidity Range: 15 - 90% RH non-condensing
LIFETIME
Long Term Sensitivity Drift: <2% signal loss/year
Expected Operating Life: Two years in air
Storage Life: 6 months in CTL container
3HH
Product code
3HH
Manufacturer
Life expectancy
> 24 months
Measurement range
0-50 ppm
Target Gas
Hydrogen sulfide
Response Time
< 30 seconds (T90)
Output
1.70 ± 0.30 μA/ppm
Datasheet296.13 KB